ENGLISH  |  JAPANESE 
 
 
Phone:+0086-512-51910068
Cell:+0086-18900616086
WeChat:18900616086
QQ:1021308596
E-mail:el-longshow@hotmail.com
 
 You are here >> All products >> Pressure Mapping Systems >> Medical Application >> t scan novus1
 
Product Code£º
t scan novus1
Specifications£º
   
 
¡¡¡¡¡¡
 
Tekscan Pressure Mapping, Force Measurement & Tactile Sensors -------- Buy Products Online (800) http://el-japan.tech -Mobile: +86-18900616086 www.elpanel.tech +1 ( www.eLdispLay.onLine ) Phone: +86-512-51910068 www.batterypaper.com Contact Us * Systems * 1. Test & Measurement 1. Pressure Mapping Systems 2. Force Measurement Systems 3. Embedded Systems 1. Foot Mapping for Retail 2. Machine Alignment 2. Biomechanics 1. Human Gait Analysis 2. Balance & Stability 3. Joint Analysis 4. Seating & Positioning 5. Veterinary 6. Pressure Offloading & Foot Function 3. Dental 1. Digital Occlusal Analysis 4. Systems By Name 1. T-Scan Novus 2. T-Scan Novus Core 3. I-Scan 4. F-Scan 5. Strideway 6. ELF 7. CONFORMat 8. TireScan 9. See All * Sensors * 1. Embedded / OEM 1. Force Sensors 1. Custom Force Sensors 2. Standard Force Sensors 3. Force Sensor Integration Kits 2. Position Sensors 2. Test & Measurement 1. Pressure Mapping Sensors 2. FlexiForce Force Sensors 3. Medical Sensors 3. Sensors By Name 1. T-Scan Sensors 2. FlexiForce A201 3. FlexiForce A301 4. FlexiForce A401 5. See All * Applications * Resources * Articles & Research * Blog * Case Studies * Datasheets & Guides * eBooks * On Demand Webinars * Testimonials * Videos * Whitepapers * See all * FlexiForce Integration Resources * Support * Contact Customer Support * Technical Support * Request Product Training * Billing Inquiries * Feedback * FAQs * Remote Support * Product Training * I-Scan 9 Tutorials * T-Scan * SportsAT Software * See All * Computer Requirements * Software Drivers * Support Contracts * Company * About Us * Technology * History * News * Events * Careers * Distributors/Contact Us * Systems * Test & Measurement * Pressure Mapping Systems * Force Measurement Systems * Embedded Systems * Foot Mapping for Retail * Machine Alignment * Biomechanics * Human Gait Analysis * Balance & Stability * Joint Analysis * Seating & Positioning * Veterinary * Pressure Offloading & Foot Function * Dental * Systems By Name * T-Scan Novus * T-Scan Novus Core * I-Scan * F-Scan * Strideway * ELF * CONFORMat * TireScan * See All * Sensors * Embedded / OEM * Force Sensors * Custom Force Sensors * Standard Force Sensors * Force Sensor Integration Kits * Position Sensors * Test & Measurement * Pressure Mapping Sensors * FlexiForce Force Sensors * Medical Sensors * Sensors By Name * T-Scan Sensors * FlexiForce A201 * FlexiForce A301 * FlexiForce A401 * See All * Applications * Resources * Articles & Research * Blog * Case Studies * Datasheets & Guides * eBooks * On Demand Webinars * Testimonials * Videos * Whitepapers * See all * FlexiForce Integration Resources * Support * Contact Customer Support * Technical Support * Request Product Training * Billing Inquiries * Feedback * FAQs * Remote Support * Product Training * I-Scan 9 Tutorials * T-Scan * SportsAT Software * See All * Computer Requirements * Software Drivers * Support Contracts * Company * About Us * Technology * History * News * Events * Careers * Distributors/Contact Us Have questions? Contact Us * LinkedIn * Facebook * Twitter * YouTube * Tekscan's FlexiForce Blog FlexiForce HT201 Sensor FlexiForce HT201 Sensor == High temperature sensor, capable of measuring force and pressure in environments as hot as 400?F (approximately 200?C). Download Datasheet FlexiForce HT201 Sensor $383.46 * Description * Specifications & Performance * Electronics * Related Products * Related Resources Description ----------- FlexiForce??HT201 Sensor ------------------------ Volume discounts icon These 3-pin sensors are capable of measuring force and pressure in environments as hot as 400?F (approximately 200?C). The HT201 measures a standard force of 222 N (50 lb), with a maximum force of 2,224 N (500 lb). The dynamic range of this versatile force sensor can be modified by changing the drive voltage and adjusting the resistance of the feedback resistor (see "How to Adjust the Force Range" within the Electronics tab on the left). HT201 Sensor Resistance and Conductance vs. Force Specifications & Performance ---------------------------- MetricU.S. Sensor Thickness: 0.203 mm (0.008 in.) Force Sensor Length7.50 in6.00 in4.00 in2.00 in Sensing Size (Diameter/Width)0.375 in Standard Force50 lbs Temperature Range (Low)-40 F Temperature Range (High)400 F Notes Ideal for high temperature applications Typical Performance?? -------------------- Linearity (Error): < ?3% of Full Scale (Line drawn from 0 to 50% load)??€? Repeatability: < ?3.5% (Conditioned Sensor, 80% of Full Force Applied) Hysteresis: < 3.6 % of Full Scale (Conditioned Sensor, 80% of Full Force Applied) Drift: <3.3% / logarithmic time (Constant Load of 111 N (25 lb)) Response Time: < 5 ?sec (Time required for the sensor to respond to an input force; Impact load - recorded on Oscilloscope) Operating Temperature: -40?C - 240?C (-40?F - 400?F) Durability: ??3 million actuations (Perpendicular load, room temperature, 22 N (5 lb)) Temperature Sensitivity: 0.36%/?C (? 0.2%/?F) (Conductive heating) ??ll data above was collected utilizing an Op Amp Circuit. If your application cannot allow an Op Amp Circuit, consult the FlexiForce Integration Guide, or contact a FlexiForce Applications Engineer. Specifications on pressures up to 500 PSI represent the average value throughout a range of temperatures up to 240?C (400?F). ??€?inearity up to 889N (200 lb) Electronics ----------- Tekscan Recommends Using an Op Amp Circuit ------------------------------------------ If your application cannot allow an Op Amp Circuit, consult the FlexiForce Integration Guide, or contact a FlexiForce Applications Engineer. If you prefer to build your own electronics, we recommend using a circuit similar to the diagram below. This will provide linear data, making it easier to calibrate the sensor. HT201 circuit diagram How to Adjust the Force Range: ------------------------------ *In order to measure higher forces, apply a lower drive voltage (-0.5 V, -0.25 V, etc.) and reduce the resistance of the feedback resistor (1k??min.) To measure lower forces, apply a higher drive voltage and increase the resistance of the feedback resistor. Related Products ---------------- Measurement Tools ----------------- If you need help selecting the best measurement tool for your application, take a look at our comparison chart or contact us. FlexiForce??OEM Development Products For: Design, OEM, and Product Engineers Tekscan offers two products created to help design engineers proceed through all phases of the FlexiForce sensor-integration process. The FlexiForce Sensor Characterization Kit helps engineers and designers to understand how FlexiForce sensors perform in a controlled loading environment. This compact kit requires very little desktop space, and eliminates the need for engineers to build their own testing fixtures. The FlexiForce Prototyping Kit allows you to efficiently progress your FlexiForce-embedded design through advanced integration phases. FlexiForce OEM Development Products ------------------------ Load Concentrators These peel-and-stick delrin FlexiForce Load Concentrators (otherwise known as "Pucks") are used to evenly distribute force across a FlexiForce sensor's sensing region, helping you optimize sensor linearity and repeatability. FlexiForce Load Concentrator ------------------------ FlexiForce Quickstart Board For: Design, Lab, OEM, and Product Engineers The FlexiForce Quickstart Board is a single source circuit that provides signal conditioning to the sensor and a linear voltage output with an applied load. It can be quickly dropped into a prototype or easily designed into a finished product. Learn More FlexiForce Quickstart Board ------------------------ Standard Multimeter (not sold by Tekscan) While standard multimeters can be used, most do not provide a constant voltage supply (which is recommended for FlexiForce sensors) and they are more difficult to calibrate compared to the tools above. Standard Multimeter Related Resources ----------------- The FlexiForce Integration Knowledge Base is a comprehensive library of useful FlexiForce sensor integration documents, articles, videos, and other useful content. Follow the button below to gain access to crtical resources for each important phase of the sensor integration process. Learn More click to access the flexiforce integration knowledge base ------------------------ Additional Resources -------------------- The FlexiForce Sensors User Manual four ways to use flexiforce sensors 4 Ways to Use FlexiForce Sensors in an Embedded Application Video: How to Calibrate Your FlexiForce Sensor Click to Access Get the eBook Watch the Video Related Products ---------------- FlexiForce Sensor Characterization Kit FlexiForce Sensor Characterization Kit The FlexiForce??Sensor Characterization Kit is a time-saving, affordable tool enabling engineers and designers to understand how FlexiForce sensors perform in a controlled loading environment. FlexiForce Prototyping Kit FlexiForce Prototyping Kit The FlexiForce??Prototyping Kit allows you to efficiently progress your FlexiForce-embedded design through advanced integration phases. Note: The FlexiForce Prototyping Kit includes an open-source software program designed specifically to help with the sensor integration process. Some code programming experience is necessary. New and improved replacement for the OEM Development Kit. Available direct from Tekscan or at Mouser.com. FlexiForce Quickstart Board FlexiForce Quickstart Board The FlexiForce Quickstart Board is a finished single voltage source circuit which can be quickly dropped into a prototype or easily designed into a product to obtain force measurements. Available direct from Tekscan or at mouser.com. FlexiForce Load Concentrators FlexiForce Load Concentrators Optimize FlexiForce sensor linearity and repeatability with these delrin load concentrators, or "pucks." Available direct from Tekscan (below) or at Digikey and Mouser. FlexiForce Analog Circuit Modules FlexiForce Analog Circuit Modules Interchangeable circuit modules for use with the FlexiForce Sensor Characterization Kit, the FlexiForce Prototyping Kit, or your own electronics. Order Online ------------ Buy Products Online Payment methods ISO 13485: 2016 Registered ISO 9001: 2008 Compliant Contact Us ---------- Find us on Google Map Global Headquarters ------------------- Tekscan, Inc. SiHai Road #11, Changshu Kechuangyuan105, Economic Development Zone, Changshu City, Jiangsu Province, China MAP IT Telephone (800) http://el-japan.tech -Mobile: +86-18900616086 www.elpanel.tech +1 ( www.eLdispLay.onLine ) Phone: +86-512-51910068 www.batterypaper.com Fax +1 ( www.eLdispLay.onLine ) 464-4266 Web Contact Us Email el-longshow@hotmail.com Quick Links ----------- * Column 1 * Test & Measurement * Embedded Sensing * Medical * Dental * Products & Solutions * Applications * Support * Resources * Column 2 Follow us --------- * LinkedIn * Facebook * Twitter * YouTube * Sitemap * Privacy Policy * Cookie Policy * Terms of Use * Disclaimers * Cookie Settings
  • On a product£º t scan novus

  • Next product£º t scan sensors supports
  • Hits£º351  Entry Time£º3/11/2025 ¡¾Print this page¡¿ ¡¾Close¡¿
    Copyright: Suzhou Long-Show Photoelectric Technology Inc. Tel :86-512 -51910068
    Pressure and Force Measurement_Thin film Pressure Sensor_Force Sensor_thin film force sensor_Pressure
    Distribution_Dental Occlusal Analysis_Body Pressure Measurement System_Pressure Mapping