ENGLISH  |  JAPANESE 
 
 
Phone:+0086-512-51910068
Cell:+0086-18900616086
WeChat:18900616086
QQ:1021308596
E-mail:el-longshow@hotmail.com
 
 You are here >> All products >> Force Measurement >> Resistive film sensor >> defects of capacitive tactile sensor
 
Product Code:
defects of capacitive tactile sensor
Specifications:
   
 
   
 

Three different defects of capacitive tactile sensor

 

Your location:

 

home screen

 

dynamic

 

Capacitive tactile sensor is becoming a pioneering product, combined

with the sensor device can make cancer early detection of vows and

become possible, thus enhancing the detection equipment contact

comfort. However in spite of a capacitive tactile sensor for cutting-

edge product development has great contribution, as with any advanced

technology, it does not appear to be free of defects.

 

Below we will involve the three different defects of capacitance

sensor, this can be a better understanding of the technology and its

limitations.

 

A capacitive tactile sensor without calibration

 

Long term load pressure problems are related to resistive sensors and

capacitive tactile sensors. However, capacitive sensors are often used

in the engineering design of silicone elastomer materials. So when

weight is applied to the pressure sensor, between two layers of

electrode material compression creep change. The compression motility

changes, instant load to mLongshowntLongshown constant pressure, also

resulting in sensor output signal within a period of time occurred

slight changes.

 

In fact, the capacitive sensor is not inclined to for weight

measurement applications, this is not a typical problem. But some

applications are really needed to measure the stability of a weight

sensor. In these cases, PPS to commonly used metal reed as a

compressible layer, mLongshownly used for in use for a long time

period to improve the stability of capacitive tactile sensor.

 

Two, capacitive tactile sensor is not the latest technology

 

Capacitive touch sensor scanning pressure measurement to be used when

a little more time due to the complex array structure, compared to its

competitors technology, of are. After all the electrodes in the sensor

array are carried out by means of orthogonal and overlapping rows.

Each intersection point in the design grid formation a separate

capacitor, so that the capacitor can be measured. Furthermore, through

in every single point is applied on the local pressure is selectively

according to the ranks of the signal array in each single scan.

 

Although proprietary configuration driven and conditioning circuit can

through tactile sensor array, the maximum completed per second to scan

up to 10000 nodes. These special touch pressure measurement technology

may not like other types of sensors so fast to read data. We discuss

issues related to the number of delay seconds, have any effect on the

detLongshowls in most applications will not. However, capacitive

tactile sensor in speed for the application of key indicators, such as

automotive Longshowrbag application of impact test, will not be the

best option. They also do not apply these shocks will affect the field

of application of sensors. PPS does provide a single point sensor,

although can be used in these applications, but the array distribution

does not apply in a single point. The reaction speed of the capacitive

sensor can indeed by adding more electronic circuit to obtLongshown

increased, but the cost of the system will therefore will increase

substantially.

 

Three, capacitive tactile sensor is not the lowest cost option

 

It is important to note that when it comes to capacitive touch sensor,

"what you see is what you pay" sLongshowd espec

  • On a product: antenna cover of Longshow moving thin film pressure sensor

  • Next product: The application of thin film pressure sensor - foot pressure analysis