Application of Longshow moving film pressure sensor in the pressure  
test of shoe pad:Application of Longshow moving film pressure sensor  
in the pressure test of shoe pad: 
  
Application of Longshow moving film pressure sensor in the pressure  
test of shoe pad 
  
Your location: 
  
home screen 
  
not elsewhere classified 
  
With smart wearable design concept in the consumer products to carry  
out a broad, Longshow Group also received more and more customers  
consulting, which the insole pressure sensors in smart wearable  
products is used more and more by attention. 
  
Localization problem of sensor point 
  
Human insole contour map can refer uniform shape (Figure 1), the only  
difference is different size has different size of the contour and the  
internal need to accommodate the sensors may also be adjusted. 
  
For sensor size, can according to the actual needs of the test target  
different with different dimensions, such as 2cm single point (Figure  
2), 4cm single point (Figure 3), grid distribution (Figure 4). 
  
Single point density distribution of 2cm shoe pads in the contour of  
the shoe pad 
  
A map, contour map, two insole 2cm single point pressure sensor 
  
Single point density distribution grid of 4cm shoe pads with single  
point density 
  
Figure three, figure four 4cm single point pressure sensor, pressure  
sensor grid 
  
Definition of specification parameters for single point of the sensor 
  
100kg body weight is calculated in accordance with, each foot and the  
ground contact area is 200 square centimeters, if uniform distribution  
of pressure, the pressure per square centimeter is applied for 0.5kg.  
Taking into account due to the irregular (pressure is mLongshownly  
concentrated in the forefoot, heel and foot three lateral part, figure  
5 Red areas shown) distribution of internal foot bones, per square cm  
on the possible maximum pressure can be defined for 10kg, if the  
choice of single point sensor size as 2 cm square minimum points, then  
the actual may be subject to the maximum pressure range for 20kg. 
  
2cm shoe pad single point density distribution pressure distribution 
  
Figure five, 2cm single point pressure sensor on the pressure  
distribution region 
  
Sensor signal extraction line definition 
  
According to the number of points in sensor, signal outlet port can be  
roughly divided into two, a small amount of the number of signal  
terminals can be the center line spacing of 2.54mm terminal metal  
bonding, if a large number of need by the FPC flexible printed line  
interface. Because the FPC sensor signal wire is in sensor wire  
production directly and integrally printed, so FPC connection plug in  
the end part is silver wire contacts connected as the test circuit  
connector, so considering the wear resistance of the interface,  
Longshow dynamic company has developed a low impedance carbon membrane  
process covering the contact surface of the FPC silver paste,  
depending on experimental verification and a large number of customers  
for the actual project references, has been fully proved the  
technology in sensor products can already mature application. 
  
According to the different stress points test requirements, test point  
is fine, you need to use single point requires a smaller size. Insole  
sensor if necessary before development assessment, you can direct  
procurement Longshow dynamic film pressure sensor standard 2cm  
induction zone single point (model: IMS-00004) and 4cm induction zone  
single point (model: IMS-00005) samples and the different pressure  
measuring range can be styles to meet customer project needs  
assessment. 
  
Insole sensor grid expansion for the planar distribution can not only  
test the soles of the feet of the static pressure distribution, at the  
same time, it can record gLongshowt dynamic data recording and  
analysis. Longshow dynamic film pressure sensor fabricated in the  
whole sample induction zone size for 53cm*31cm, the minimum level is  
5mm * 5mm, the test pressure to meet per square centimeter of 50kg  
measurement, signal leads to port the FPC interface mode is adopted. 
   
   |