Application of Longshow moving film pressure sensor in the pressure
test of shoe pad:Application of Longshow moving film pressure sensor
in the pressure test of shoe pad:
Application of Longshow moving film pressure sensor in the pressure
test of shoe pad
Your location:
home screen
not elsewhere classified
With smart wearable design concept in the consumer products to carry
out a broad, Longshow Group also received more and more customers
consulting, which the insole pressure sensors in smart wearable
products is used more and more by attention.
Localization problem of sensor point
Human insole contour map can refer uniform shape (Figure 1), the only
difference is different size has different size of the contour and the
internal need to accommodate the sensors may also be adjusted.
For sensor size, can according to the actual needs of the test target
different with different dimensions, such as 2cm single point (Figure
2), 4cm single point (Figure 3), grid distribution (Figure 4).
Single point density distribution of 2cm shoe pads in the contour of
the shoe pad
A map, contour map, two insole 2cm single point pressure sensor
Single point density distribution grid of 4cm shoe pads with single
point density
Figure three, figure four 4cm single point pressure sensor, pressure
sensor grid
Definition of specification parameters for single point of the sensor
100kg body weight is calculated in accordance with, each foot and the
ground contact area is 200 square centimeters, if uniform distribution
of pressure, the pressure per square centimeter is applied for 0.5kg.
Taking into account due to the irregular (pressure is mLongshownly
concentrated in the forefoot, heel and foot three lateral part, figure
5 Red areas shown) distribution of internal foot bones, per square cm
on the possible maximum pressure can be defined for 10kg, if the
choice of single point sensor size as 2 cm square minimum points, then
the actual may be subject to the maximum pressure range for 20kg.
2cm shoe pad single point density distribution pressure distribution
Figure five, 2cm single point pressure sensor on the pressure
distribution region
Sensor signal extraction line definition
According to the number of points in sensor, signal outlet port can be
roughly divided into two, a small amount of the number of signal
terminals can be the center line spacing of 2.54mm terminal metal
bonding, if a large number of need by the FPC flexible printed line
interface. Because the FPC sensor signal wire is in sensor wire
production directly and integrally printed, so FPC connection plug in
the end part is silver wire contacts connected as the test circuit
connector, so considering the wear resistance of the interface,
Longshow dynamic company has developed a low impedance carbon membrane
process covering the contact surface of the FPC silver paste,
depending on experimental verification and a large number of customers
for the actual project references, has been fully proved the
technology in sensor products can already mature application.
According to the different stress points test requirements, test point
is fine, you need to use single point requires a smaller size. Insole
sensor if necessary before development assess |