Wiper force distribution measurement system
Wiper can measure the force distribution of the wiper blade on the glass under various environmental conditions. This system can be used to research and develop wiper, blade and other products, so that the wiper can achieve better results. Wiper system includes USB data acquisition device, operation software, balance / correction device (model ා pb5d) and Tekscan's patented thin (0.004 in / 0.1mm) bendable sensor, which can measure the dynamic pressure distribution graph between driving, and the measurement result depends on different conditions such as driving speed, wind speed and wiper swing position. It is not easy to design a wiper that can clean the glass effectively. There are many limitations, such as different length, hardness, uneven pressure, curvature of glass bending, complex mechanical driving structure, and various wind pressure conditions, which cause many challenging problems in material selection and dynamic design. Wiper system can measure the whole rain The pressure distribution of the brush provides you with an important insight into how to improve your design and overcome these complex problems.
Detailed introduction
application
Wiper design – this system is designed for this application
Key features
Dynamic recording and rewind observation
Ability of drawing and analysis
Real time observation
Flexible film sensor
Along the length direction, the sensing piece contains nearly 100 independent sensing points
The sensing piece is durable and reusable
Simple USB connection
portable
High sensitivity
System optimization application
Professional engineer team support
Applicable units
R & D lab, design & test department
Applicable industries
Wiper & automobile industry
Software features
Dynamic power data capture
Wiper blade angle display
Real time 2-D and 3-D pressure image recording and observation
Support video rewind operation (video recording)
Grid by grid display of observation data
ASCII file output
Measurement image display supports cell or multi grid animation playback
Independent analysis of specific scope
Simultaneous observation and comparison of multiple weight measurement results
And more
Introduction of sensing film
Model of sensing piece
Nine thousand nine hundred and one
Nine thousand nine hundred and twenty
Sensing points
Ninety-six
One hundred and twenty-eight
spatial resolution
4.0sensels/linear in
(1.57sensels/linear cm)
4.0 sensels/linear in
(1.57 sensels/linear cm)
Sensing area
24 in x 0.4 in
(610 mm x 11 mm)
32 in x 0.81 in
(813 mm x 20.5 mm)
technology
Piezoresistive
Correcting
Use force control device to carry out field measurement and correction
Sampling frequency
8 Hz
Pressure range
0-10 PSI
thickness
0.004 in (0.1mm)
Optional add ons
Wireless Capabil
Wireless operation module can provide a wireless connection device for your sensor and computer, so that |